§535.232 Standards of Practice: Minimum Inspection Requirements for Appliances
General provisions
The inspector is not required to:
- operate or determine the condition of other auxiliary components of inspected items;
- test for microwave oven radiation leaks;
- inspect self-cleaning functions;
- disassemble appliances;
- determine the adequacy of venting systems; or
- determine proper routing and lengths of duct systems.
Dishwashers
The inspector shall report as Deficient:The inspector shall:
- inoperative units;
- deficiencies in performance or mounting;
- rusted, missing or damaged components;
- the presence of active water leaks; and
- the absence of backflow prevention.
Food waste disposers
The inspector shall report as Deficient:
- inoperative units;
- deficiencies in performance or mounting;
- missing or damaged components; and
- the presence of active water leaks.
Range hoods and exhaust systems
The inspector shall report as Deficient:
- inoperative units;
- deficiencies in performance or mounting;
- missing or damaged components;
- ducts that do not terminate outside the building, if the unit is not of a re-circulating type or configuration; and
- improper duct material.
Electric or gas ranges, cooktops, and ovens
The inspector shall report as Deficient:
- inoperative units;
- missing or damaged components;
- combustible material within thirty inches above the cook top burners;
- absence of an anti-tip device, if applicable;
- gas leaks;
- the absence of a gas shutoff valve within six feet of the appliance;
- the absence of a gas appliance connector or one that exceeds six feet in length;
- gas appliance connectors that are concealed within or extended through walls, floors, partitions, ceilings or appliance housings; and
- deficiencies in:
- thermostat accuracy (within 25 degrees at a setting of 350° F);
- mounting and performance;
- gas shut-off valves;
- access to a gas shutoff valves that prohibits full operation; and
- gas appliance connector materials.
Microwave ovens
The inspector shall inspect built-in units and report as Deficient:
- inoperative units;
- deficiencies in performance or mounting; and
- missing or damaged components.
Mechanical exhaust systems and bathroom heaters
The inspector shall report as Deficient:
- inoperative units;
- deficiencies in performance or mounting;
- missing or damaged components;
- ducts that do not terminate outside the building; and
- a gas heater that is not vented to the exterior of the building unless the unit is listed as an unvented type.
Garage door operators
The inspector shall report as Deficient:
- inoperative units;
- deficiencies in performance or mounting;
- missing or damaged components;
- installed photoelectric sensors located more than six inches above the garage floor; and
- door locks or side ropes that have not been removed or disabled.
Dryer exhaust systems
The inspector shall report as Deficient:
- missing or damaged components;
- the absence of a dryer exhaust system when provisions are present for a dryer;
- ducts that do not terminate to the outside of the building;
- screened terminations; and
- ducts that are not made of metal with a smooth interior finish.